Size solar strings from real datasheets, in seconds.
Check any panel against any inverter, microinverter or optimizer. Tera Labs applies the NEC 690.7 cold-temperature correction for your city and lays out the whole project, from one roof to a thousand panels.
Everything you need before you order equipment
Tools sharing one verified data set, so a panel you check in the String Sizer has exactly the same numbers in the comparison and the database.
String Sizer
Minimum, maximum and best string length for any panel and inverter at your site's temperatures.
Size a string →Project calculator
Enter inverters, strings or total panels and get the rest, including exact-fit string mixes.
Plan a project →Datasheet Compare
Two panels, inverters or optimizers side by side: electrical, thermal, size, look and warranty.
Compare specs →Equipment database
Every model with its full spec sheet, a to-scale drawing and a compatibility table.
Browse models →Compatibility checker
Every panel against every inverter: yes or no, string range and panels per inverter.
Check a pairing →Electrical calculators
Wire size, voltage drop, conduit fill, the 120% rule and fuse sizing, with the NEC rule shown.
Open calculators →Three steps, real engineering math
No black box. Every result shows the formula and the datasheet numbers behind it.
Pick equipment and location
Choose a panel, an inverter (or microinverter) and an optimizer if you use one. Type your city to load its design temperature.
We correct for temperature
Voc is raised for the coldest morning, Vmp is lowered for the hottest afternoon, and current limits are checked per MPPT.
Get strings and a layout
See every string length that fits, then size the project: inverters, strings, panels, kWp and DC/AC ratio.
Common combinations, already checked
Results at a −10 °C record low and a 40 °C hottest day. Open any row to change the location or the numbers.
Brands in the database
Starting with the equipment US installers use most, and growing every week.
Built to be trusted on a real job
Straight from the datasheet
Every model links to the manufacturer document it came from. Values from distributor listings are clearly marked.
Transparent math
NEC 690.7 coefficient method, NMOT-based cell temperatures and per-MPPT current checks, shown step by step.
Local design temperatures
ASHRAE 2017 extreme annual mean minimums for 976 US cities, or use your current location.
How many solar panels can I put in one string?
Divide the inverter's maximum DC input voltage (or the module's max system voltage, whichever is lower) by the module's open-circuit voltage at your coldest expected temperature, then round down. A typical residential string of 400–450 W modules on a 500–600 V inverter lands around 10–14 panels. The String Sizer does this for every pairing in the database.
Which temperature should I use for the record low?
Use the ASHRAE extreme annual mean minimum design dry-bulb temperature for the nearest weather station. Pick your city in the String Sizer and it fills this in from ASHRAE 2017 data for 976 US cities.
Do microinverters need string sizing?
No. Each microinverter takes one or two modules, so the check is whether the module fits the input window (max voltage, MPPT range, current and recommended power) and how many units fit on a 20 A branch circuit.
How is SolarEdge different?
SolarEdge optimizers hold the string at a fixed voltage (380 V on 240 V inverters), so string length depends on optimizer count and power per string (5,700 W usable, up to 6,800 W connected on 7.6 kW+ inverters with two or more strings) rather than module voltage.
Can I use these results for a permit?
Treat them as a fast first check. Always confirm the design with the inverter maker's own sizing tool, the current datasheet and your authority having jurisdiction.
Planning a bigger project?
Our design team can take it from string layout to a full design and equipment order.
Questions, corrections or a project in mind?
Send us a message and a real person will reply. Spotted a value that doesn't match a datasheet? That's the most useful thing you can tell us.
- Missing a model?
Send its datasheet and we'll add it with its own page. - A result looks off?
Tell us the panel, the inverter and your city, and we'll check the math. - Need a full design?
Our design team takes projects from layout to equipment order.