Size solar strings from real datasheets, in seconds.

Check any panel against any inverter, microinverter or optimizer. Tera Labs applies the NEC 690.7 cold-temperature correction for your city and lays out the whole project, from one roof to a thousand panels.

Specs linked to every datasheetASHRAE design temperaturesNo sign-up
Solar array with a string-check result showing 11 panels fit
1357solar panels from 76 brands
105inverters & microinverters
9optimizers (SolarEdge, Tigo)
976US cities with design temperatures
The toolkit

Everything you need before you order equipment

Tools sharing one verified data set, so a panel you check in the String Sizer has exactly the same numbers in the comparison and the database.

How it works

Three steps, real engineering math

No black box. Every result shows the formula and the datasheet numbers behind it.

1

Pick equipment and location

Choose a panel, an inverter (or microinverter) and an optimizer if you use one. Type your city to load its design temperature.

2

We correct for temperature

Voc is raised for the coldest morning, Vmp is lowered for the hottest afternoon, and current limits are checked per MPPT.

3

Get strings and a layout

See every string length that fits, then size the project: inverters, strings, panels, kWp and DC/AC ratio.

Popular pairings

Common combinations, already checked

Results at a −10 °C record low and a 40 °C hottest day. Open any row to change the location or the numbers.

Coverage

Brands in the database

Starting with the equipment US installers use most, and growing every week.

APsystemsAdani SolarAptos SolarAstronergyAuxin SolarAxitecBYDBoviet SolarCPS (Chint Power)Canadian SolarDMEGCDehui SolarEG4Elite SolarEmmveeEnphaseFirst SolarFroniusG-StarGCLGermanSolarGoldi SolarGreen EnergyHT-SAAEHaitai SolarHansolHelieneHoymilesHyperionHyundaiIDN SolarIlluminate USAJA SolarJinko SolarKosolLGLOF SolarLONGiMaxeonMeyer BurgerMission SolarNEPNew East SolarPanasonicPeimarPhiladelphia SolarPhono SolarPremier EnergiesPrism SolarQcellsRECRNGRayzon SolarRisenRunergyS-EnergySEG SolarSMASaatvikSeraphimShinsungSilfabSirius PVSol-ArkSolar4AmericaSolarEdgeSolariaSolexSolisSonali SolarSunPowerSunSparkSunproSuntechTalesunTata Power SolarTeslaThornovaTigoTopsunTrina SolarUREUS SolarVSUNVikram SolarWaareeYingliZNShine
Why Tera Labs

Built to be trusted on a real job

Straight from the datasheet

Every model links to the manufacturer document it came from. Values from distributor listings are clearly marked.

Transparent math

NEC 690.7 coefficient method, NMOT-based cell temperatures and per-MPPT current checks, shown step by step.

Local design temperatures

ASHRAE 2017 extreme annual mean minimums for 976 US cities, or use your current location.

FAQ

Questions installers ask

Short answers to what comes up most. Something else? Ask us below.

How many solar panels can I put in one string?

Divide the inverter's maximum DC input voltage (or the module's max system voltage, whichever is lower) by the module's open-circuit voltage at your coldest expected temperature, then round down. A typical residential string of 400–450 W modules on a 500–600 V inverter lands around 10–14 panels. The String Sizer does this for every pairing in the database.

Which temperature should I use for the record low?

Use the ASHRAE extreme annual mean minimum design dry-bulb temperature for the nearest weather station. Pick your city in the String Sizer and it fills this in from ASHRAE 2017 data for 976 US cities.

Do microinverters need string sizing?

No. Each microinverter takes one or two modules, so the check is whether the module fits the input window (max voltage, MPPT range, current and recommended power) and how many units fit on a 20 A branch circuit.

How is SolarEdge different?

SolarEdge optimizers hold the string at a fixed voltage (380 V on 240 V inverters), so string length depends on optimizer count and power per string (5,700 W usable, up to 6,800 W connected on 7.6 kW+ inverters with two or more strings) rather than module voltage.

Can I use these results for a permit?

Treat them as a fast first check. Always confirm the design with the inverter maker's own sizing tool, the current datasheet and your authority having jurisdiction.

Planning a bigger project?

Our design team can take it from string layout to a full design and equipment order.

Talk to our design team ↗
Contact

Questions, corrections or a project in mind?

Send us a message and a real person will reply. Spotted a value that doesn't match a datasheet? That's the most useful thing you can tell us.

  • Missing a model?
    Send its datasheet and we'll add it with its own page.
  • A result looks off?
    Tell us the panel, the inverter and your city, and we'll check the math.
  • Need a full design?
    Our design team takes projects from layout to equipment order.

We reply by email, usually within two working days.